EPG 125P 125 kW Diesel Generator: 250-Gallon Subbase Fuel Tank, In Stock and Ready to Ship

November 10, 2026

When a power outage threatens production, critical systems, or a project schedule, generator capacity is only part of the decision. Fuel planning matters just as much. The EPG Model 125P, SKU 40516GS12, pairs a 125 kW diesel genset with a 250-gallon subbase fuel tank. An integrated configuration that gives facility teams a practical starting point for emergency-runtime planning.

This unit is listed in stock at Mid-America Engine in Warrior, Alabama. It is a new, 2023 set with factory test hours only. MAE has supplied industrial power solutions for more than 40 years, with an engineering-driven approach and honest recommendations. The goal is to help buyers evaluate what the equipment can do for their application, not promise performance the available data cannot support.

View the EPG 125P product listing.

A 125 kW package with fuel storage built in

The 250-gallon subbase tank mounts beneath the generator, combining fuel storage and the genset in one package. That can simplify equipment layout compared with planning a separate tank installation, subject to site requirements, clearances, and applicable codes.

The verified listing details include:

  • Generator: EPG Model 125P, 125 kW
  • Fuel: Diesel
  • Engine: John Deere Model 4045HF285
  • Alternator: Leroy Somer, model LSA44.810J 6/4
  • Electrical output: 120/208 V, three-phase, 12 leads, fully reconnectable
  • Controls: Deep Sea
  • Breaker: 600 A
  • Enclosure: Sound attenuated
  • Tank: 250-gallon subbase fuel tank
  • Dimensions: Approximately 170 in. L × 41 in. W × 95 in. H
  • Approximate weight: 7,000 lb

The product page uses the EPG 125P name; its equipment records identify the set as EPG125JD-series. Buyers should confirm the unit identity and configuration against the nameplates and documentation as part of the purchasing and application review.

Subbase fuel tank mounted beneath the EPG 125P diesel generator

Plan for runtime with a fuel curve, not tank capacity alone

A 250-gallon tank is a useful planning input, but it does not by itself establish how long the generator will run. Actual runtime depends on fuel consumption at the operating load, the engine’s fuel curve, usable tank volume, site conditions, and the operating limits used in the facility’s plan.

For a 24-, 48-, or 72-hour outage scenario, start with the expected load profile, not just the generator’s 125 kW rating. A genset may operate at varying loads as equipment starts, cycles, or is shed. The fuel consumed per hour will change accordingly. Use the applicable fuel-consumption data at the anticipated load points, then account for the facility’s required reserve and refueling strategy.

A practical review should cover:

  1. Critical and noncritical loads. Identify which systems must remain online and whether load shedding is part of the response plan.
  2. Expected generator loading. Estimate the normal outage load and any periods of higher demand, including motor starts.
  3. Usable fuel and operating reserve. Do not assume the full nominal tank volume is available for planned consumption. Confirm usable capacity and relevant equipment limits.
  4. Refueling logistics. Consider fuel access, delivery lead times, site access during severe weather, and who is authorized to arrange delivery.
  5. Monitoring and response. Define how operators will track fuel level and when they will initiate replenishment.

For this unit, MAE has not supplied a verified runtime figure or fuel-consumption curve in the listing. We will not convert “250 gallons” into a guaranteed number of operating hours. Request the appropriate fuel data and review it against your actual loading and contingency requirements before finalizing an outage plan.

Sound attenuation helps with siting decisions

The generator is mounted in a sound-attenuated enclosure. For industrial facilities, contractors, and other sites where equipment location affects nearby work areas or neighboring properties, an enclosed configuration can support a more considered layout than an open unit.

Enclosure type alone does not determine whether a proposed location is suitable. Review the site’s ventilation and exhaust needs, service access, foundation and lifting requirements, clearances, electrical routing, and local noise requirements. The listed dimensions-170 inches long, 41 inches wide, and 95 inches high, along with an approximate weight of 7,000 pounds, are useful for early planning. Confirm final handling and installation requirements with the project team.

Control panel for EPG generator SKU 40516GS12

Engine, alternator, and controls

The set uses a John Deere 4045HF285 engine and a Leroy Somer alternator. The alternator is listed as model LSA44.810J 6/4, with 120/208 V, three-phase output and 12 reconnectable leads. That configuration gives the project team specific information to check against the facility’s voltage, phase, and connection requirements.

Deep Sea controls are specified on the unit. The panel and control documentation should be reviewed during application planning to confirm that the equipment’s interfaces and operating functions fit the intended system. The listing also specifies a 600 A breaker; final electrical coordination should account for the site distribution equipment, protection scheme, and installation design.

John Deere 4045HF285 engine identification plate for SKU 40516GS12

The John Deere engine model is clearly identified in the product records. Parts availability and service requirements depend on the specific application, location, and component needs. MAE can help buyers review the engine and set details and identify the information needed for a practical support plan, without assuming a part is available or promising a service outcome before it is confirmed.

In stock in Warrior, Alabama, with domestic freight options

This unit is listed as in stock and FOB Warrior, AL. It is approximately 170 in. long, 41 in. wide, 95 in. high, and 7,000 pounds, so freight and offloading should be planned before dispatch. MAE offers prepay-and-add freight to domestic locations across the United States. Share the delivery location and site constraints to request a freight quote.

The product page lists a price of $41,489.29. Price and availability can change, so confirm both when requesting a quote.

Explore other generator sets or contact Mid-America Engine to discuss your application.

Request a quote for SKU 40516GS12

If your project calls for a 125 kW diesel set with an integrated 250-gallon subbase tank, the EPG 125P is available to review now. When you contact MAE, include your required voltage, phase, expected load, delivery ZIP code, and target schedule. That gives the team a clearer basis to discuss fit, fuel planning, and freight.

With more than 40 years in industrial power, Mid-America Engine focuses on dependable equipment, practical engineering review, and honest recommendations. Request a quote for the EPG Model 125P, SKU 40516GS12.

Frequently asked questions

How long will the EPG 125P run on its 250-gallon tank?

A verified runtime cannot be determined from tank capacity alone. Runtime depends on the fuel-consumption curve at the actual load, usable tank volume, operating conditions, and planned reserve. Request the applicable fuel data and compare it with your expected load profile.

What electrical output is listed for this generator?

The listing identifies 120/208 V, three-phase output, a 12-lead fully reconnectable Leroy Somer alternator, and a 600 A breaker. Confirm the configuration and compatibility with your electrical design before purchase.

Is this generator in stock and where is it located?

The product listing identifies SKU 40516GS12 as in stock in Warrior, Alabama. Confirm current availability and price directly with Mid-America Engine.

Can Mid-America Engine arrange shipping?

Yes. The unit is FOB Warrior, AL, and MAE offers prepay-and-add freight to domestic U.S. locations. Request a freight quote with your delivery location and any site-access details.

What is the difference between the 125P listing name and the EPG125JD-series records?

The storefront lists the generator as EPG Model 125P, while the unit records identify the set as EPG125JD-series. Confirm the exact unit identity and equipment documentation with MAE when requesting a quote.

Table of Contents

More Posts